Laserfiche WebLink
INSTRUCTIONS FOR PREPARATION OF A SITE PLAN <br /> Site plan must be current,drawn to scale,and show all property lines and dimensions. <br /> MARUNTY IONS <br /> CO <br /> ITEMS THAT MUST BE SHOWN ON YOUR SITE PLAN: <br /> ❑ 1. NORTH ARROW. <br /> ❑ 2. SCALE OF DRAWING: the site plan must be drawn to scale, indicate scale used. Scale <br /> must be easily readable. If unable to draw to scale,property lines must still b own noting <br /> actual dimensions and total acreage. <br /> ❑ 3. ALL PROPERTY LINES AND DIMENSIONS—existing and pro ed. <br /> ❑ 4. FENCES,RETAINING WALI.S—l:ocation of existing and/or pp posed. <br /> ❑ 5. EXISTING AND,PkOROS`E S1'RTJCTURES -label as"Pr posed"and "Existing". <br /> Include dimensions and distance to all property lines and other structures. <br /> D 6. EXISTING AND PROPOSED DRIVEWAYS,ROADS,INTERNAL ROADS, <br /> PARKING AND CIRCULATION AREAS—label as "Paved"or "Gravel. " Show <br /> driveway to public right-of-way. Label the STREET NAME accessing the parcel. <br /> ❑ 7. PARTITIONING(if applicable)—proposed new property line shown by dashed lines,with <br /> parcels labeled as "Parcel 1", "Parcel 2", etc. <br /> ❑ 8. WELLS—existing and proposed on this parcel and adjacent parcels within 100 feet. <br /> Neighboring wells must be shown. Irrigation wells must be shown. <br /> ❑ 9. CUTS/FILLS—show existing and proposed. <br /> ❑ 10. UTILITY LINES AND EASEMENTS. <br /> ❑ 11. STORM WATER SYSTEMS OR DETENTION BASINS—show existing and proposed. <br /> ❑ 12. FLOODPLAIN—if applicable, show the boundary of the 100 year floodplain. <br /> ❑ 13. GEOGRAPHIC FEA S—ground slope and direction of slope, escarpments, streams, <br /> ponds, or other drainage , ays. <br /> ❑ 14. EXISTING SEPTIC : STEM—Initial System and Replacement Area. <br /> Initial Site Evaluation: <br /> ❑ 15. TEST HOL : —show distances between holes and property Iines. One test hole should <br /> be located the center of the area proposed for the initial system. Locate the other test <br /> hole in t center of the proposed replacement area. Accurately locate the test holes on the <br /> site ph diagram. , <br /> Installation P: mit: <br /> ❑ 16. EST HOLES—accurately show the location of the test holes.,; ,;', `; ; • <br /> ❑ 17. Follow any pre-Permit requirements listed in the Site Evaluation Approv`ai Report or <br /> pre-permit Letter. j•'. <br /> ❑ 1: SYSTEM PLACEMENT—Both initial system and replacement system tiiiistbe <br /> shown. Separation distances for items requiring setbacks must be indicated. Show <br /> septic tank and distance from structure; show disposal trench lengths and distances <br /> between trenches. <br /> ❑ 19. Construction Details: Must include size and type of tank(s),distribution or drop boxes; <br /> type of drainfield material;pump, alarm and float components, setting and control details; <br /> control panel specifications. Hydraulic calculations(pump selection curve). This <br /> information can be listed, or supplied as manufacturer spec sheets. <br /> ❑ 20. ELEVATIONS—at lot corners or construction area and at corners of building site. <br /> FAILURE TO INCLUDE ALL OF THE ITEMS LISTED ABOVE MAY <br /> DELAY THE REVIEW NECESSARY TO OBTAIN A PERMIT! <br />