My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
12016141
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
23-XXXXXX
>
12016141
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/6/2024 9:48:25 AM
Creation date
1/19/2024 3:25:35 PM
Metadata
Fields
Template:
Permits
Permit Address
7836 BURTON PL SE
Permit City
Salem
Permit Number
555-23-010340-EVAL
Parcel Number
082W02C 00200
Permit Type
Site Evaluation
Permit Doc Type
Permit Document
Status
Ready to Film
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
4 <br /> Oregon Department of Environmental Quality <br /> * The septic tank material is: <br /> ( x Concrete <br /> Steel <br /> Plastic <br /> Fiberglass <br /> 1 Other(explain) <br /> FT Unknown <br /> * <br /> Is the septic tank accessible? IT Yes No <br /> * Septic tank volume in gallons 1,000 <br /> * Tank volume determined by:Check all that apply,add comments below as needed <br /> x Permit Records 1 x I Measured Stamped on Tank I (Other <br /> * Septic tank risers are at ground level x Yes No <br /> * Tank appears to be free from defects, leaking and signs of deterioration x Yes No <br /> If you answered "No," please describe the condition of the septic tank below. For example, <br /> evidence of gas corrosion,cracks,leaks,etc. <br /> * Septic tank lid(s) is intact x Yes No <br /> * Septic tank baffles are intact: Inlet x Yes No Outlet © es 1----)Vo <br /> * Baffle material-Inlet 17, Plastic Concrete Metal <br /> Outlet X Plastic Concrete Metal <br /> * Effluent filter is present Yes I x l No <br /> * Effluent filter is free of debris Yes No x Not applicable <br /> * Liquid level in tank relative to invert of outlet x At Above Below <br /> If above or below invert outlet,please explain: <br /> * Scum layer 1 (inches) Sludge layer 6 (inches) <br /> * Scum and Sludge layer more than 35%of the total tank volume Yes x No <br /> Indicate where sludge measured from: s Inlet Middle x Outlet <br /> * Additional comments: <br /> PERFORMED A 150 GALLON FLOW TEST WITH FOW METER. <br /> 4. Dosing Tank/Pump Basin <br /> Dosing tanks use a pump to send effluent to a treatment unit or soil absorption field. <br /> * The septic system has a dosing tank I 1Yes x No <br /> (If"No,"skip the rest of section 4) <br /> * At the time of this evaluation the power was on to test the pump(s): Yes No <br /> Page 3 of 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.