Laserfiche WebLink
Orenco Technical Data Sheet <br /> oellik S-Series Simplex Control Panels <br /> Applications . General • <br /> Orenco®S-Series Simplex Control Panels control single pumps in Orenco®S-Series Simplex Control Panels are electro-mechanical <br /> effluent sewer(STEP)systems,onsite septic systems,and for pump panels for controlling single pumps.Standard features include an <br /> control into conventional gravity sewer systems. Automatic/Off/Manual (Auto/Off/Man)toggle switch,controls circuit <br /> breaker,pump circuit breaker,automatic motor control operation,and <br /> an audible/visible high water level alarm with auto reset.Specifications <br /> for standard and optional features are listed on page 2. <br /> �- _-�� —•-�-_ All S-Series control panels have a 120 VAC controls circuit breaker.Si <br /> y s. ""' �� • panels have a 120 VAC pump circuit breaker,while S2 panels have a <br /> ..�.) 240 VAC pump circuit breaker. <br /> �r <br /> * , -'INA All S-Series panels can be used with both mechanical and mercury <br /> •� li <br /> ._ . ,i . -• float switches. <br /> =— fi • Di Listed per UL-508 and cUL-508; CE-listed versions of S-Series panels <br /> are available. <br /> ..11 . .- • ..1:.,..._......-----. • ' 411!-- p <br /> Orenco S-Series Simplex Control Panel(S1ETMCT shown) Standard Models <br /> S1,S2 <br /> Materials of Construction Product Code Diagram <br /> .04 <br /> Component Material S i <br /> Enclosure UN-resistant fiberglass,Type 4X(IP 66) <br /> Hinge Stainless steel I Standard options(list in order): <br /> PT = programmable timer <br /> Latch Stainless steel RO = redundant off relay <br /> ETM = elapsed time meter <br /> CT = event counter <br /> Specifications HT = heater <br /> PRL = pump run light <br /> Feature Specifications PL = power light <br /> SA = surge arrestor <br /> Height,in.(mm) 11.5(292) TS = test switch <br /> Width,in.(mm) 9.3(236) Intrinsically safe relays: <br /> Depth,in.(mm) 5.4(137) Blank = standard,no IR relays <br /> S1 panel ratings* 120 VAC,1 hp(0.75 kW),16 A,1-phase,60 Hz IR = intrinsically safe relays <br /> S2 panel ratings* 240 VAC,3 hp(2.24 kW)16 A,1-phase,60 Hz Pump voltage: <br /> "Pump motors used with these panels require internal overload protection. 1 =120 VAC <br /> 2=120 VAC or 240 VAC <br /> S Series simplex control panel <br /> Orenco Systems®Inc.,814 Airway Ave.,Sutherlin,OR 97479 USA•800-348-9843•541-459-4449•www.orenco.com NTD-CP-S-1 <br /> Rev.1.1,©08/14 <br /> Page 1 of 2 <br />