Laserfiche WebLink
Pump Selection for a Non-Pressurized System -Single Family Residence Project <br /> Bruce Wolf/555-19-001532-PRMT <br /> Parameters <br /> Discharge Assembly Size 1.25 inches 400 <br /> Transport Length 310 feet <br /> Transport Pipe Class 40 <br /> Transport Line Size 2.00 inches <br /> Distributing Valve Model None <br /> Max Elevation Lift 15 feet 350 <br /> Design Flow Rate 10 gpm <br /> Flow Meter None inches <br /> 'Add-on'Friction Losses 0 feet <br /> Calculations 300 <br /> Transport Velocity 0.9 fps <br /> Frictional Head Losses <br /> Loss through Discharge 0.7 feet PF1005I <br /> Loss in Transport 0.6 feet v 250 <br /> Loss through Valve 0.0 feet <br /> Loss through Flowmeter 0.0 feet <br /> 'Add-on'Friction Losses 0.0 feet <br /> d <br /> Pipe Volumes I 200 <br /> Vol of Transport Line 54.0 gals E <br /> co <br /> Minimum Pump Requirements <br /> Design Flow Rate 10.0 gpm ;o 150 <br /> Total Dynamic Head 16.3 feet H <br /> 100 <br /> 50 <br /> 0 <br /> 0 <br /> 0 5 10 15 <br /> Net Discharge(gpm) <br /> PumpData Legend <br /> PF1005 High Head Effluent Pump SystemLurve: <br /> 10 GPM,1/2HP <br /> 115/230V 10 60Hz,200V 30 60Hz Pump'Ct rve: <br /> Pump Optimal Range: <br /> 0 <br /> Operating Point: <br /> 0 <br /> Design Point: <br /> Orenco <br /> SYSTEMS <br />