Laserfiche WebLink
. . . , <br /> , . <br /> Orenco _ , . . . <br /> T E R r <br /> Product Code Diagram <br /> BPP -On - Mr- Ir1T- ,Sx -n- <br /> Discharge assembly;details: <br /> SDI = HV100BCFCX;field-cut,1 in PVC,ball valve,check valve,flow control,10gpm pumps only <br /> SD2 = HV100BCX;field-cut,1 in PVC,ball valve,check valve,10 or 20gpm pumps <br /> SD3 = HV125BCX;field-cut,1.25in PVC,ball valve,check valve,30gpm pumps <br /> SD4 = HV200BCX;field-cut,2in PVC,ball valve,check valve,50gpm pumps <br /> CW1 = HV100BCFCX+HVCW100-KIT;field-set,1 in PVC,ball valve,check valve,flow control,10gpm pumps only <br /> CW2= HV100BCX+HVCW100-KIT;field-set,1 in PVC,ball valve,check valve,10 or 20gpm pumps <br /> CW3= HV125BCX+HVCW125-KIT;field-set,1.25in PVC,ball valve,check valve,30gpm pumps <br /> CW4= HV200BCX+HVCW200-KIT;field-set,2in PVC,ball valve,check valve,50gpm pumps <br /> DB1 = HV100B-DB;field-set,ball valve,drainback,10 or 20gpm pumps <br /> DB2 = HV125B-D8;field-set,ball valve,drainback,30gpm pumps <br /> DB3 = HV2006-DB;field-set,ball valve,drainback,50gpm pumps <br /> HD1 = HDA24125FCASLC-FS;field-set,1.25in hose,flow control,P01 (PF100511 CV)pump only <br /> HD2 = HDA24125ASLC-FS;field-set,1.25in hose,P01 (PF100511 CV)pump only <br /> HD3 = HDA24125CFCASLC-FS;field-set,1.25in hose,check valve,flow control,10gpm pumps only <br /> HD4 = HDA24125CASLC-FS;field-set,1.25in hose,check valve,10,20,or 30gpm pumps <br /> Pump vault height,in(mm),for 18in(450mm)diameter filter: <br /> 48 = 48(1219)PVU-Series 60 = 60(1524)PVP-Series <br /> 57 = 57(1448)PVU-Series 55 = 55(1397)PV-Series <br /> 68 = 68(1727)PVU-Series <br /> Splice box options: <br /> SB = Internal splice box <br /> SX = External splice box <br /> Float switch 8 pump cord lengths,ft(m): <br /> 10= 10(3) _ <br /> 20= 20(6) <br /> Control panel;float switches: STATE CERTIFIED <br /> S1l = St;3P M11 = MVP-S1DM;3P Environmental Health Specialist <br /> 4 0 <br /> S12 = S1ETMCT;3P M12= MVP-SIDMHT;3P '� �'A. EH-S-10206540 <br /> S13 = S1HR;2P M13= MVP-S1DMHTSA;3P `�'" <br /> S14 = S1PTR0;2BN M14= MVP-SIDMHTMTSGR-NC;3P <br /> S15 =S1PTROETMCT;2BN M15= MVP-S1DM(DEMAND);3P �` �� <br /> S16 =S1RO;3PN M21 = MVP-S2DM;3P <br /> S17 = SIROETMCT;3PN M22= MVP-S2DMHT;3P _fbeGoodwjnf r <br /> S18 = S1 ROETMCTSA;3PN M23= MVP-S2DMHTSA;3P <br /> S19 = S1ROMTSGR-NC;3PN A-1 <br /> Submersible effluent pump model;details: Y <br /> P01 = PF100511 CV;10gpm(0.6Usec),0.50hp(0.37Kw),120V P12= PF300512;30gpm(1.9Usec),0.50hp(0.37kW),240V <br /> for HD1 and HD2 only P13= PF300712;30gpm(1.9Usec),0.75hp(0.56kW),120V <br /> P02= PF1 00511;10gpm(0.6Usec),0.50hp(0.37kW,120V P14 = PF301012;30gpm(1.9Usec),1.00hp(0.75kW),240V <br /> P03= PF100512;10gpm(0.6Usec),0.50hp(0.37kW),240V P15= PF500511;50gpm(3.2Usec),0.50hp(0.37kW),120V <br /> PO4= PF100712;10gpm(0.6Usec),0.75hp(0.56kW),240V P16= PF500512;50gpm(3.2Usec),0.50hp(0.37kW),240V <br /> P05= PF101012;10gpm(0.6Usec),1.00hp(0.75kW),240V P17= PF500712;50gpm(3.2Usec),0.75hp(0.56kW),240V <br /> P08= PF200511;20gpm(1.3Usec),0.50hp(0.37kW),120V P18= PF501012;50gpm(3.2Usec),1.00hp(0.75kW),240V <br /> P09= PF200512;20gpm(1.3Usec),0.50hp(0.37kW),240V P90= PVA100511;10gpm(0.6Usec),0.50hp(0.37kW),120V <br /> P10= PF201012;20gpm(1.3Usec),1.00hp(0.75kW),240V P91 = PVA300511;30gpm(1.9Usec),0.50hp(0.37kW),120V <br /> P11 = PF300511;30gpm(1.9Usec),0.50hp(0.37kW),120V P92= PVA500511;50gpm(3.2Usec),0.50hp(0.37kW),120V <br /> Biotubee ProPak' <br /> NTD-BPP-1 Orenco Systems*•800-348-9843•+1 541-459-4449•www.orenco.com <br /> Rev.5008121 <br /> Page 2 el 2 <br />