Laserfiche WebLink
22017t5-Nicole/36'Stock QV:,2. Truss-^: sm K <br /> Customer. Conifer Pacific,Inc Oregon Truss SID: <br /> �R TRUSGONFIkS <br /> Infoeoregontruss.com TID: <br /> TRUSS 503-581-8787 Date: 01/18/22 <br /> Truss Mfr.Contact:Taml Heath ,..We're Just Better Page: 1 of 1 <br /> 6-9-1 5-2-12 6-0-3 6-0-3 5-2-12 6-9-1 <br /> 6-9-1 11-11-13 18-0-0 24-0-3 5 29-2-15 6 36-0-0 <br /> 1 2 3 4 <br /> 7 <br /> 6x6= <br /> 4J12 -4/12 <br /> 3x6pm 3x6pm <br /> cnro 2x4pm 2x4pm <br /> 0 <br /> 6x16 • 6x16 <br /> 7-8 i•':; 1 7-8 <br /> 4x10pm 5x8-18 4x1Bpm ', 'i, ' • J <br /> 12-4-1 11-3-14 12-4-1.i.r21 <br /> I <br /> 1 '','12-4-1 8 23-79-15 10 36-0-0 7 <br /> 1 -36-0-01 <br /> Truss Weight - 220.8 lb <br /> Code/Design: IBC-2018/TPI-2019 Snow Load Specs--------- Wind Load Specs Additional Design Checks <br /> PSF Live Dead Our Factors ASCE7-16 Ground Snow(Pg) ..',25.0-psf ASCE7-16 Wind Speed(V) - 120 mph 10 psf Non-Concurrent BCLL: No <br /> TC 25.0 7.0' Live Wind Snow Risk Cat: I Terrain Cat: B" Risk Cat: I Exposure Cat: B 20 psf BC Limited Storage: No <br /> BC 0.0 1,0 Lum 1.25 1.60 1.15 Roof Exposure: Partially Exposed Bldg Dims: L - 0.0 ft B = 0.0 ft 200 lb BC Accessible Ceiling: No <br /> Total 33.0 Plt 1.25 1.60 1.15 Thermal Condition: Dnheated(1.2) M.R.H(h) = 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load: No <br /> Spacing: 7o-00n00-o.c. Plies: 1 Unobstructed Slippery Roof: Yes Bldg Enclosure: Partially Enclosed 2000 lb TC Safe Load: No <br /> Repetitive Member Increase: No Low-Slope Minimums(Pfmin): No Wind DL(paf): TC = 4.2 BC = 0.6 Unbalanced TCLL: Yes <br /> Green Lumber: No Wet Service: No Unbalanced Snow Loads: Yes End Vertical Exposed: L - Yes R= Yes <br /> Fab Tolerance: 05 Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No Wind Uplift Reporting: ASCE7 MWFRS <br /> Lu(max) = 20-00-00 C&C End Zone: 3-07-03 <br /> Material Summary Reaction Summary Deflection Summary <br /> TC 2x6 DFL 1800/1.8 TrussSpan Limit Actual(in) Location <br /> BC 2x6 DFL 1800/1.8 Reaction Summary(Lbs) Vert LL L/240 L/626(-0.68) 8-10 <br /> Webs 2x4 DFL Standard Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI <br /> 1 02-12 4234 1185 05-08 05-05 SPF 531 Vert DL L/120 L/999(-0.23) 8-10 <br /> 2x4 DFL 12 4-10 8-4 7 35-09-04 4234 1185 05-08 05-05 SPF 531 Vert CR L/180 L/468(-0.91) 8-10 <br /> Wedge 2x4 DFL Standard Max Horiz - -217 / +217 at Joint 1 Horz LL 1.00in ( 0.18) @Jt 7 <br /> Hors CR 1.50in ( 0.23) @Jt 7 <br /> Member Forces Summary Loads Summary MPL CR L/120 L/714(-0.19) 8-10 <br /> Max CSI in TC PANEL 3 - 4 0.83 This truss has been designed for the effects of an unbalanced top chord Bracing Data Summary <br /> Max CSI in BC PANEL 1 - 8 1.00 live load occurring at [18-00-00) using a 1.00 Full and 0.00 Reduced load Bracing Data <br /> Max CSI in Web 2 - 8 0.97 factor. Chords; Sheathing required or bracing <br /> This truss has been designed for a concurrent moving point ao,1b=Lave Load indicated: <br /> ...Mem... Ten Comp .CSI. and 0 lb Dead Load applied to the bottom chord starting at 0'ind ending at Purlins <br /> TC 1- 2 5077 9966 0.81 36-00-00.The point loads are applied at 2-0-0 on-center locations; total ---oc--- --From-- ---To--- iBays <br /> 2- 3 4546 8623 0.82 load deflection limits = L/120. TC 2-00-00 0 36-00-00 19 <br /> 3- 4 4815 8558 0.83 BC 6-00-00 0 36-00-00 6 <br /> 4- 5 4815 8558 0.83 See Loadcase Report for loading combinations and additional details. Web Bracing -- CIA <br /> 5- 6 4547 8623 0.82 Single: 8- 4 4-10 <br /> 6- 7 5076 9966 0.81 Notes Continuous Restraint Bracing Req'd <br /> BC 1- 8 9258 4654 1.00 Plates designed for Cq at 1.00 and Rotational Tolerance of 0.0 degrees See BCSI-B3 3.0 <br /> 7-10 9258 4583 1.00 A "pm" next to the plate size indicates that the plate has been user <br /> 8- 9 5967 2785 0.72 modified; see Plate Offsets for any special positioning requirements. Plate offsets(X,Y): <br /> 9-10 5967 2785 0.72 Continuous Lateral Restraint (CLR) rows require diagonal bracing per (None unless indicated below) <br /> Web 2- 8 790 1506 0.97 D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. Jnt3(0,00-04), Jnt,5(0,00-04), <br /> 3- 8 934 1354 0.41 Jnt8(-00-13,00-08* Jnt10(00-13,00-08), <br /> 4- 8 2816 1578 0.49 Jntl(07-03,01-03), Jnt7(-07-03,01-03) <br /> 4-10 2816 1578 0.99 <br /> 5-10 934 1354 0.41 <br /> 6-10 789 1506 0.97 <br /> NOTICE Acopy of this design shell be furnished to the erection contractor.The design of this individual truss is based on design criteria and requirements supplied by Component Solutions <br /> the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer.A seal on this drawing indicates SIMPSON Truss studio V <br /> acceptance of professional engineering responsibility solely for the truss component design shown.See the cover page and the'Important Information&General ,yd^vr 2021.5.0.261 <br /> Notes'page for additional information.Al connector plates shall be manufactured by Simpson Strong-Tie Company,Inc in accordance with ESR-27822.All connector <br /> plates are 20 gauge,unless the specified plate size is followed by a"-18'which indicates an 18 gauge plate,or'Sit 18',which Indicates a high tension 18 gauge plate. 1,. n ' <br /> Ecatrw:2021h5GT <br />