My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
11988913
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
23-XXXXXX
>
11988913
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/21/2023 8:00:15 PM
Creation date
12/21/2023 4:30:09 PM
Metadata
Fields
Template:
Permits
Permit Address
15296 WOODBURN-MONITOR RD NE
Permit City
Woodburn
Permit Number
555-23-006639-PRMT
Parcel Number
051W25DD01400
Permit Type
Septic
Permit Doc Type
Permit Document
Status
Ready to Film
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Oregon Department of Environmental Quality <br /> g• septic tank material is: <br /> Concrete <br /> 0 Steel <br /> 0 Plastic <br /> 0 -Fiberglass <br /> 0 Other(explain) <br /> 0 unknown <br /> . Is the septic tank accessible? es ON° <br /> • Septic took volume in gallons (OD in <br /> din <br /> • Tank volume determined by: Check all that apply,add co cuts below as needed <br /> 0 Permit Records 0 Measured 0 Stepped on Tank Other <br /> • Septic tank risers are at ground level ibIllYes ON° <br /> • Tank appears to be free from defects,leaking and signs of deterioration[]Yes U‘o <br /> If you answered"No,"please describe the condition of the septic tank below.For example, <br /> evidence of gas corrosion,cracks,leaks,etc. <br /> ke'C-ftrouttpl:...II i <br /> i <br /> • Septic tank lid(s)is intact DIres Nod <br /> • Septic tank bafflesE <br /> are intact Inlet afes No Outlet OYes [:]No <br /> • Baffle material-Inlet OPlaptic concrete Ddetal Outlet Plastic OConerete DMetal <br /> • Effluent filter is present ISnYes ON° <br /> • Effluent filter is free of debris ElYes No :Not Applicable <br /> • Liquid level in tank relative to invert of outlet DAL DAbove elow <br /> If above or below invert outlet,please explain: <br /> • Sewn layer Ai I ,(inches) Sludge layer 1/ i (inches) <br /> • Scum and Sludge layer more than 35%of the total m i volume OYes ONo <br /> Indicate where sludge measured from Ellidet Diddle [(Outlet <br /> • Additional Comments: I <br /> lot^K evica.i.C 't d. ced- eJ v,11) <br /> 4. Dosing tank/Pump Basin <br /> Dosing tanks use a pump to send effluent to a tr--.: -nt unit or a soil absorption field. <br /> • • The septic system has a dosing tank EiYes No <br /> • Of'No,"skip the rest of section 4) <br /> • At the time of this evaluation the power was on to test the pump(s): . Yes EINo <br /> Page 3 of 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.