Laserfiche WebLink
Septic Permit 555-23-006639-PRMT Page 2 of 3 <br /> A F; <br /> WAR tic 0AJ JILtw <br /> • <br /> 'rT w -3' a x e. `si€ c a w't5 ^, ja. s '^xv off, s. <br /> 4t1 it n s <br /> .„, .... -�... ..... .... ..�°,wm.�,a .�,m.�.,.- �� sue,s\F.w ...,.a....:..:�.._ r .,. _ '‘flpfprgyp <br /> •This permit is a reasonable repair,it is for placing the dwelling at 15296 Woodburn-Monitor Road on a holding tank. <br /> This is considered a permanent solution to the failure unless it is demonstrated that a siting requirement can be met for <br /> a drainfield facility to serve this dwelling. <br /> •An anti-buoyancy device is required for the septic tank(s)and must be installed as per the manufacturer installation <br /> guidelines. <br /> •The alarm be set at 75%of tank volume and must be wired on separate circuits in the control panel.Alarm wiring <br /> must comply with applicable building,electrical,or other codes.An electrical permit and inspection from the <br /> Department of Consumer and Business Services,Building Codes Division,or the municipality with jurisdiction, is <br /> required for pump wiring installation. <br /> •Properly decommission the old septic tank and submit appropriate documentation. <br /> •A failing system must be repaired as soon as possible.Should the repair of this system be delayed,the property owner must <br /> notify the agent and provide the reasons for delay,and propose a different completion date.Delays may be cause for formal <br /> enforcement action,which may result in civil penalty assessments. <br /> •The system must be installed by the property owner or a licensed sewage disposal business(installer). <br /> •AII tanks must be tested for watertightness and have a water-tight riser to the ground surface.Twenty-inch minimum diameter if <br /> less than 36-in deep.Thirty-inch minimum diameter if greater than 36-in deep.Maintain access to septic tank for pumping and <br /> service. <br /> •A minimum 18-gauge,green jacketed tracer wire or green color-coded metallic tape must be placed on top of the effluent sewer <br /> or pressure transport pipe from tank to drainfield. <br /> •The system must be installed in the area approved during the site evaluation and in accordance with the construction plan <br /> approved by the agent, including any changes made by the agent. <br /> •All work is to conform to OAR 340, Division 71 and 73.Make no changes in system location or specifications without approval <br /> by the agent. <br /> •For product approval information and manufacturer installation requirements see DEQ website at: <br /> http://www.oregon.gov/deq/Residential/Pages/Onsite.aspx <br /> Installation of this onsite wastewater treatment system has been determined to comply with the applicable requirements in <br /> Oregon Administrative Rules Chapter 340, Divisions 071 and 073 and the Conditions of Approval above. <br /> 1. In accordance with Oregon Revised Statute 454,665,this Certificate of Satisfactory Completion is issued as evidence of <br /> satisfactory completion of an onsite wastewater treatment system at the location identified above. <br /> 2. Issuance of this Certificate does not constitute a warranty or guarantee that this onsite wastewater treatment system will <br /> function indefinitely without failure.Conditions imposed as permit requirements continue for the life of the system. <br /> 3.The area of the initial and the identified replacement area must not be subjected to activity that is likely to adversely affect <br /> the soil or the functioning of the system.Such activities may include, but are not limited to,vehicular traffic,livestock, <br /> covering the area with asphalt or concrete,filling,cutting,or other soil modification activities. <br /> 4.This onsite wastewater treatment system that be connected to the facility referenced herein within 5 years of the issuance <br /> of this Certificate of Satisfactory Completion(CSC)or rules for authorization notices,alteration permits,or <br /> construction-installation permits as outlined in OAR 340-071-0160,340-071-0205,or 340-071-0210 apply,including payment <br /> of an additional fee. <br /> 5.This system must operate in compliance with OAR Chapter 340, Division 071 and must not create a public health hazard <br /> or pollute public waters. <br /> 6.Unless otherwise required by the agent,the system installer must backfill(cover)this system within 10 days after the <br /> issuance of this Certificate of Satisfactory Completion. <br /> 12/5/23:4:45:23PM ONS_OnsiteCSC pr <br />