Laserfiche WebLink
Onsite Permit 555-23-007231-PRMT Page 2 of 3 <br /> Schedule or track inspections at www.buildingpermits.oregon.gov <br /> Call or text the word "schedule"to 1-888-299-2821 use IVR Number:555041368960 <br /> Schedule using the Oregon ePermitting Inspection App, search"epermitting"in the app store <br /> 4'a . � W�" p t�`t Y ,•°"my����' a xpiratfor;� �Tt24 <br /> Work crtpttatilltaAJ'RE 3 t DR Fl r 3 a a a q <br /> y a �, P �,� '. s y ,,, '" t ry``- �,,,°s �..�, *:, , <br /> �,..�:� .,>.�_ �5aa:��,,, xs°s'...� a�,�3',@..d;.��a�, �� <br /> Max depth: 36 in. Undisturbed soil between trenches: 10 ft. <br /> Min depth: 24 in. Capping fills-min depth of fill material: N/A <br /> Special Requirements <br /> Groundwater type: Not Applicable Groundwater depth: N/A <br /> Pump to drainfield reqd: N/A Filter fabric on top of drain media: Yes <br /> Conditions of approval <br /> •Dry soil installation only(June 1 —October 1 unless otherwise authorized by the agent). <br /> •The system must be installed by the property owner or a licensed sewage disposal business(installer). <br /> •Vehicular traffic and livestock must be restricted from the system area. <br /> •All roof drains must be directed away from the system <br /> •AII tanks must be tested for watertightness and have a water-tight riser to the ground surface.Twenty-inch <br /> minimum diameter if less than 36-in deep.Thirty-inch minimum diameter if greater than 36-in deep.Maintain <br /> access to septic tank for pumping and service. <br /> .Meet all required setbacks <br /> •The system must be installed in the area approved during the site evaluation and in accordance with the <br /> construction plan approved by the agent,including any changes made by the agent. <br /> All work is to conform to OAR 340,Division 71 and 73. Make no changes in system location or specifications <br /> without approval by the agent. <br /> •For product approval information and manufacturer installation requirements see DEQ website at: <br /> http://www.oregon.govideq/Residential/Pages/Onsite.aspx <br /> •A minimum 18-gauge,green jacketed tracer wire or green color-coded metallic tape must be placed <br /> on top of the effluent sewer or pressure transport pipe from tank to drainfield. <br /> Effluent sewer.The effluent sewer must extend at least 5 feet beyond the septic tank before connecting to the <br /> distribution unit. It must be installed with a minimum fall of 4 inches per 100 feet and at least 2 inches of fall from <br /> one end of the pipe to the other. In addition,there must be a minimum difference of 8 inches between the invert of <br /> the septic tank outlet and either the invert of the header to the distribution pipe of the highest lateral in a serial <br /> distribution field or the invert of the header pipe to the distribution pipes of an equal distribution absorption field. <br /> •Header pipe from Distribution or Drop Box must be minimum 4-ft length, level,and bedded. <br /> .Each drainfield trench must be level within a tolerance of plus or minus 1-inch. <br /> •Maximum length of an individual trench is 150-feet. <br /> •Serial distribution,each trench bottom to be level and on contour.Use Drop box(es). <br /> •Properly decommission the old septic tank and submit appropriate documentation. <br /> 9/28/23:8:33:18AM ONS_OnsitePermit_pr <br />