My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
11983037
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
23-XXXXXX
>
11983037
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/21/2023 2:42:55 PM
Creation date
12/18/2023 4:13:34 PM
Metadata
Fields
Template:
Permits
Permit Address
6561 BRUSH CREEK DR NE
Permit City
Silverton
Permit Number
555-23-006343-EVAL
Parcel Number
061W29D 00100
Permit Type
Site Evaluation
Permit Doc Type
Permit Document
Status
Ready to Film
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Building Inspection Division <br /> ���c -.- Onsite Septic Review <br /> " l.. OREGO.N <br /> iiiiPUB1:1C:INPRKS= <br /> Activity Number: 555-23-006343-EVAL Date: September 12, 2023 <br /> Project Address: 6561 Brush Creek Dr NE, Silverton <br /> 061 W29D 00100; 9.85 Acres <br /> Completed By: Aidan Bammes,REHS <br /> ONSITE WASTEWATER TREATMENT SYSTEM SITE EVALUATION <br /> DENIAL <br /> Site Limitations <br /> Relevant site features were evaluated during the site visit on August 1st' 2023. The conditions observed <br /> during the site evaluation indicate that the area where the test pits were located does not meet minimum <br /> standards established by the Department of Environmental Quality. The area evaluated is denied for onsite <br /> wastewater treatment. <br /> Most sites have some limitations that will affect the location or type of wastewater system that may be <br /> installed; however,the area of the site that was evaluated is not capable of supporting any Standard or <br /> Alternative septic system due to the following limitations: <br /> Temporary water table is 9" below the surface. <br /> DEQ Rule requirement: <br /> Depth of the Temporary (perched)Water Table must be at least 24 inches below the surface for a <br /> standard system, and at least 12 inches below the surface for a sand filter or alternative treatment <br /> technology system under OAR 340-071-0220(1)(b) & OAR 340-071-0290(2)(a). The depth to <br /> temporary water table in the area evaluated is 9". <br /> Alternatives—Where to Go From Here <br /> As described above,the soil conditions at this site do not qualify for a subsurface treatment system. <br /> The following options are available: <br /> Apply to connect the shop to the main house system with a pump tank.This will require a minor alteration <br /> permit which can be applied for at Marion County Public works, a permit application packet is attached. <br /> Please submit a site plan and a list of the materials to be used including an approved tank specification for <br /> the State of Oregon. <br /> 5155 Silverton Road NE—Salem,Oregon 97305—Phone(503)588-5147—Fax(503)588-7948 <br /> Page 1 of 3 <br />