Laserfiche WebLink
Orenco. e et h cal t ata S : { 1 �� <br /> SYSTEMS „ r <br /> e <br /> t , Air vent(on optional flow modulation plate) <br /> (�• Discharge orifice(on optional flow modulation plate) <br /> • I � <br /> A B C <br /> gi gig <br /> v T w <br /> Specifications <br /> Model FTS0444-36,FTW0444-36 FTS0436-28,FTW0436-28 <br /> A-Vault height,in.(mm) 44.00(1118) 36.00(914) <br /> B-Cartridge height,in.(mm) 36.00(915) 28.00(710) <br /> C-Inlet hole height,*in.(mm) 21.25(540) 19.25(489) <br /> D-Nominal diameter,in.(mm) 4.00(100) 4.00(100) <br /> Number of inlet holes 8 8 <br /> Inlet hole diameter,in.(mm) 1.13(29) 1.13(29) <br /> Discharge orifice diameter,in.(mm) 4.00(100) 4.00(100) <br /> Discharge coupling diameter,in.(mm) 4.00(100) 4.00(100) <br /> Filter surface area, ft2(m2) 5.1 (0.50) 3.9(0.40) <br /> Flow area,"ft2(m2) 1.5(0.15) 1.2(0.12) <br /> Flow Modulation Plate(Optional) <br /> Number of discharge orifices 2 <br /> Discharge orifice diameter,in.(mm) 0.50(12.7) <br /> Number of air vents 1 <br /> Air vent diameter,in.(mm) 0.50(13) <br /> Inlet hole height can vary depending on the configuration of the tank.Optimum hole height is 70%of the minimum liquid level. <br /> T Filter area is defined as the total surface area of all individual Biotubes®within the filter cartridge. <br /> "Flow area is defined as the total open area(or area of the mesh openings)of all the individual Biotubes within the filter cartridge. <br /> NTD-FT-FTS-1 Orenco Systems®Inc.,814 Airway Ave.,Sutherlin,OR 97479 USA•800-348-9843•541-459-4449•www.orenco.com <br /> Rev.3.0,©05/18 <br /> Page 2 of 2 <br />