Laserfiche WebLink
Onsite Permit 555-23-006684-PRMT Page 2 of 3 <br /> Schedule or track inspections at www.buildingpermits.oregon.gov <br /> Call or text the word "schedule" to 1-888-299-2821 use IVR Number:555089452115 <br /> Schedule using the Oregon ePermitting Inspection App, search"epermitting"in the app store <br /> Date issued 8f t 3123 C r ,f Expiration date`8/12/24 <br /> Work descnpt,on NI"U1t4 N TALL 4 BDRM SFD a <br /> Min depth: 24 in. Capping fills-min depth of fill material: N/A <br /> Special Requirements <br /> Groundwater type: Temporary Groundwater depth: N/A <br /> Other special rqmt: APPLICANT HAS SPECIFIED 475 LINEAR FEET OF DRAINFIELD WHERE ONLY 450 IS REQUIRED <br /> Conditions of approval <br /> •Dry soil installation only(June 1 —October 1 unless otherwise authorized by the agent). <br /> •An anti-buoyancy device is required for the septic tank(s)and must be installed as per the <br /> manufacturer installation guidelines. <br /> •The system must be installed by the property owner or a licensed sewage disposal business(installer). <br /> •Vehicular traffic and livestock must be restricted from the system area. <br /> •All roof drains must be directed away from the system <br /> -All tanks must be tested for watertightness and have a water-tight riser to the ground surface.Twenty-inch <br /> minimum diameter if less than 36-in deep.Thirty-inch minimum diameter if greater than 36-in deep. Maintain <br /> access to septic tank for pumping and service. <br /> •Meet all required setbacks <br /> •The system must be installed in the area approved during the site evaluation and in accordance with the <br /> construction plan approved by the agent, including any changes made by the agent. <br /> •All work is to conform to OAR 340,Division 71 and 73.Make no changes in system location or specifications <br /> without approval by the agent. <br /> •For product approval information and manufacturer installation requirements see DEQ website at: <br /> http://www.oregon.gov/deq/Residential/Pages/Onsite.aspx <br /> •A minimum 18-gauge,green-jacketed tracer wire or green color-coded metallic tape must be placed on top of <br /> the effluent sewer or pressure transport pipe from tank to drainfield. <br /> Effluent sewer.The effluent sewer must extend at least 5 feet beyond the septic tank before connecting to the <br /> distribution unit. It must be installed with a minimum fall of 4 inches per 100 feet and at least 2 inches of fall from <br /> one end of the pipe to the other. In addition,there must be a minimum difference of 8 inches between the invert of <br /> the septic tank outlet and either the invert of the header to the distribution pipe of the highest lateral in a serial <br /> distribution field or the invert of the header pipe to the distribution pipes of an equal distribution absorption field. <br /> • •Header pipe from Distribution or Drop Box must be minimum 4-ft length,level,and bedded. <br /> •Each drainfield trench must be level within a tolerance of plus or minus 1-inch. <br /> •Maximum length of an individual trench is 150-feet. <br /> •Serial distribution, each trench bottom to be level and on contour.Use Drop box(es). <br /> •Groundwater Interceptor,Curtain Drain required: Minimum trench width 12-inches.Minimum perf pipe diameter <br /> 4-inches;must meet the requirements in OAR 340-073-0060(4);and must be installed at least 2 inches above the <br /> bottom and along the full length of the trench with a minimum of 10 inches of drain media cover The curtain drain <br /> must be filled with drain media to within 12 inches of the ground surface with filter fabric placed over the media. <br /> The outlet pipe(s)must be rigid smooth-wall,solid PVC pipe meeting or exceeding ASTM Standard D-3034 with a <br /> minimum diameter of 4 inches.A flap gate or rodent guard must be installed.The curtain drain must extend at <br /> least 6 inches into the layer that limits effective soil depth or to a depth adequate to effectively dewater the site. <br /> 9/25/23:12:31:23PM ONS_OnsitePermit_pr <br />