`..q, Marion County
<br /> Silverton Rd NE
<br /> rt�
<br /> 5
<br /> Septic Authorization Approval 515Salem,OR 97305
<br /> Marion
<br /> County 503-588-5147
<br /> 555-23-009539-AUTH Building@co.marion.or.us
<br /> O;REGO14
<br /> Residential Authorization Website:co.marion.or.us
<br /> zv � �� -� � s' 4v 1.a woxiolce 4V00P°'p�i g� 9�..�.��r + *. x��o,�,�. x' ?,'s .,�`f
<br /> Date Issued:1211112 Date Exp r►ng 1211B12 F f �4
<br /> rkof ..� t.a+q ` �,7'aw q P`3 •; S ^�''`fs'+"
<br /> 100:tclltlo t1 T *PL2BD§PRIAT12BD SFD . � '
<br /> g
<br /> -14M, ,,yam ..5;t4.h n.ti.r.,.* , .,,rAe, . .: .;-?��--.< . :.,..'. rt .,. � �` f �'. 4 ad
<br /> Applicant: SCHULER,TIMOTHY
<br /> Address: 4837 WILLINGTON CT NE
<br /> SALEM OR 97305
<br /> Phone: 503-559-0838
<br /> Email: TIMSCHULER@COMCAST.NET
<br /> Owner: SCHULER,TIMOTHY Property Address: 25537 Taylor Park Rd SE,Lyons,OR
<br /> Address: 4837 WILLINGTON CT NE 97358
<br /> SALEM OR 97305
<br /> Parcel:092E10DC01500-Primary
<br /> Authorization Notice for: Replacing One Dwelling with Another
<br /> Lot Size: 0.48 Acre Water Supply: Well
<br /> Category of Construction: Single Family Dwelling
<br /> ,.ter«:
<br /> °���n-`- :..yy,..�<„-..�-., ,. .,�''_, `xr: ;,±,E::, -:' � ����, ..,�a..:,., �ro..,�i.a�S'�.�.�s�^. +,` �... .�. ,_r.."' 9..<,..E, � P{`1i p�.?`e�,��;. -. �r✓.
<br /> Use of Structure: 2BDRM Single Family 2BDRM Single Family
<br /> Dwelling Dwelling
<br /> Number of Bedrooms: 2 2
<br /> System Specifications:
<br /> Max Peak Design Flow: 150 gpd Proposed Gallons per Day: 300 gpd
<br /> Other Special Requirement: This property was affected by the Beachie Creek fire.The system consists of 120 linear feet of
<br /> existing drainfield and a 1000-gallon septic tank installed in 2007 under permit 555-07-01149.This
<br /> lot was created in 1940,and therefore a setback of less than 100ft to the well is allowed under OAR
<br /> 340-071-0220(1)(j)(B).Under OAR 340-071-0205(4)the authorization is approved to connect to a
<br /> 2BDRM Single Family Dwelling.
<br /> Conditions of Approval:
<br /> Note:This Notice does not guarantee satisfactory or continuous operation of the sewage system.Should the system fail,a repair
<br /> permit from DEQ is required.
<br /> If you disagree with this report,you have the right to apply for an authorization notice denial review.The application for review must
<br /> be submitted in writing within 45 days of the report issuance and be accompanied by the review fee in OAR 340-071-0140(3),Table
<br /> 9C and any additional information DEQ needs to complete the review.
<br /> You may apply for a variance to the onsite wastewater treatment system rules. The variance application must include a copy of
<br /> the site evaluation report,plans and specifications for the proposed system,specify the rule(s)to which a variance is being
<br /> requested,demonstrate the variance is warranted,and include the variance fee in OAR 340-071-140 Table 9C. A variance may
<br /> only be granted if the variance officer determines that strict compliance with a rule is inappropriate or special physical conditions
<br /> render strict compliance unreasonable,burdensome or impractical. A senior DEQ variance officer will be assigned the variance
<br /> application.
<br /> CALL BEFORE YOU DIG...ITS THE LAW
<br /> ATTENTION:Oregon law requires you to follow rules adopted by the Oregon Utility Notification Center. Those rules are set forth by Oregon Administration Rules. You may obtain
<br /> copies of the rules by calling the center.(Note:The telephone number for the Oregon Utility Notification Center is 1-800-332-2344.)
<br /> 12/11/23:8:24:28AM Page 1 of 2 ONS_OnsiteAuthorizationur