My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
11971586
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
23-XXXXXX
>
11971586
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/26/2023 1:20:35 PM
Creation date
12/8/2023 4:44:42 PM
Metadata
Fields
Template:
Permits
Permit Address
20521 BRIDGE CREEK RD SE
Permit City
Silverton
Permit Number
555-23-008752-INQY
Parcel Number
081E01B 00100
Permit Type
SEPTIC
Permit Doc Type
Permit Document
Status
Ready to Film
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Oregon Department of Environmental Quality <br /> • The septic tank material is: <br /> g Concrete <br /> ❑ Steel <br /> ❑ Plastic <br /> ❑ Fiberglass <br /> O Other(explain) <br /> ✓ Unknown <br /> • Is the septic tank accessible? ®Yes ❑No <br /> • Septic tank volume in gallons 1,000 <br /> • . Tank volume determined by:Check all that apply,add comments below as needed <br /> ❑Permit Records®Measured El Stamped on Tank❑Other <br /> • Septic tank risers are at ground level DYes ®No 18"Deep <br /> • Tank appears to be free from defects,leaking and signs of deterioration®Yes ❑No <br /> If you answered"No,"please describe the condition of the septic tank below.For example, <br /> evidence of gas corrosion,cracks,leaks,etc. <br /> • Septic tank lid(s)is intact ®Yes DNo <br /> • Septic tank baffles are intact:Inlet ®Yes ❑No Outlet ®Yes ❑No <br /> • Baffle material-Inlet rIPlastic PIConcrete [Metal Outlet rPlastic 121Concrete [Metal <br /> Effluent filter is present ['Yes ZNo <br /> • Effluent filter is free of debris DYes ❑No Not Applicable <br /> • Liquid level in tank relative to invert of outlet At ['Above ['Below• <br /> If above or below invert outlet,please explain: <br /> • Scum layer 1 (inches) Sludge layer 12 (inches) <br /> • Scum and Sludge layer more than 35%of the total tank volume DYes ®No <br /> Indicate where sludge measured from:❑Inlet ❑Middle ['Outlet <br /> • Additional Comments: <br /> Tank appears to be in good condition at this time <br /> 4. Dosing tank/Pump Basin <br /> Dosing tanks use a pump to send effluent to a treatment unit or a soil absorption field. <br /> • The septic system has a dosing tank ['Yes ®No <br /> (If"No,"skip the rest of section 4) <br /> • At the time of this evaluation the power was on to test the pump(s): ['Yes ❑No <br /> Page 3 of 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.