Laserfiche WebLink
Onsite Permit 555-23-006732-PRMT Page 2 of 3 <br /> Schedule or track inspections at www.buildingpermits.oregon.gov <br /> Call or text the word "schedule" to 1-888-299-2821 use IVR Number:555065249235 <br /> Schedule using the Oregon ePermitting Inspection App, search"epermitting"in the app store <br /> Bate issued 8I15123 d ,' E iration date 8/14124 <br /> Work d4scnption MIN REP 3 BDRM SFD � i ��� <br /> 3 f <br /> Conditions of approval <br /> •Dry soil installation only(June 1 —October 1 unless otherwise authorized by the agent). <br /> •The system must be installed by the property owner or a licensed sewage disposal business <br /> (installer). <br /> -Vehicular traffic and livestock must be restricted from the system area. <br /> -All roof drains must be directed away from the system <br /> •AII tanks must be tested for watertightness and have a water-tight riser to the ground surface. <br /> Twenty- inch minimum diameter if less than 36-in deep.Thirty-inch minimum diameter if greater than <br /> 36-in deep. Maintain access to septic tank for pumping and service. <br /> -Meet all required setbacks <br /> •The system must be installed in the area approved during the site evaluation and in accordance <br /> with the construction plan approved by the agent, including any changes made by the agent. <br /> •All work is to conform to OAR 340, Division 71 and 73. Make no changes in system location or <br /> specifications without approval by the agent. <br /> for product approval information and manufacturer installation requirements see DEQ website at: <br /> http://www.oregon.gov/deq/Residential/Pages/Onsite.aspx <br /> •A minimum 18-gauge, green jacketed tracer wire or green color-coded metallic tape must <br /> be placed on top of the effluent sewer or pressure transport pipe from tank to drainfield. <br /> •Effluent sewer.The effluent sewer must extend at least 5 feet beyond the septic tank before <br /> connecting to the distribution unit. It must be installed with a minimum fall of 4 inches per 100 feet and <br /> at least 2 inches of fall from one end of the pipe to the other. In addition, there must be a minimum <br /> difference of 8 inches between the invert of the septic tank outlet and either the invert of the header to <br /> the distribution pipe of the highest lateral in a serial distribution field or the invert of the header pipe to <br /> the distribution pipes of an equal distribution absorption field. <br /> 8/15/23:8:28:41AM ONS_OnsitePermit_pr <br />