My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
11857425
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
22-XXXXXX
>
11857425
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/28/2023 11:29:47 AM
Creation date
9/20/2023 2:05:27 PM
Metadata
Fields
Template:
Permits
Permit Address
295 HUMBUG ST S
Permit City
Detroit
Permit Number
555-22-001787-PRMT
Parcel Number
105E01CB02500
Permit Type
Septic
Permit Doc Type
Permit Document
Status
Ready to Film
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Onsite Permit 555-22-001787-PRMT Page 2 of 3 <br /> Schedule or track inspections at www.buildingpermits.oregon.gov <br /> Call or text the word "schedule" to 1-888-299-2821 use IVR Number:555065704782 <br /> Schedule using the Oregon ePermitting Inspection App, search"epermitting"in the app store <br /> Date4 issutef8122122 y 1 s Exptratrvn date 8122123 <br /> A <br /> Work 46:0ptra RWEC A REPAOStb <br /> Seepage bed specs: 500 square feet. Laterals 2'from Bottomless sand filter sqft: N/A <br /> sidewall max and 4'spacing max. <br /> orifices 1/8"diameter and 24" <br /> spacing.Sweep each line to grade <br /> with valve box. Last orifice of each <br /> line to be facing down to prevent <br /> freezing and growth. <br /> Media type: Rock/Pipe Media depth: 12 in. <br /> Trench length: N/A Rock above pipe: 3 in. <br /> Total rock depth: 12 in. Rock below pipe: 8 in. <br /> Max depth: 22 in. Undisturbed soil between trenches: N/A <br /> Min depth: 18 in.. Capping fills-min depth of fill material: N/A <br /> Special Requirements <br /> Stake out required: Yes <br /> Groundwater type: Temporary Groundwater depth: 28 in. <br /> Groundwater interceptor: Yes Groundwater interceptor depth: N/A <br /> Pump to drainfield reqd: Yes Filter fabric on top Of drain media: Yes <br /> Conditions of approval <br /> •This repair permit is for replacement of the existing septic system following the Lionshead Fire of 2020 which <br /> burned this property. <br /> •Properly decommission the old septic tank and submit appropriate documentation. <br /> •Pressurized distribution rules at OAR 340-071-0275. Install sweep elbows at ends of lateral piping with <br /> acceptable threaded plugs or caps. Minimum head of 5-ft at remotest orifice, less than 10%variation. <br /> •Dry soil installation only(June 1 —October 1 unless otherwise authorized by the agent). <br /> •The system must be installed by the property owner or a licensed sewage disposal business(installer). <br /> •Vehicular traffic and livestock must be restricted from the system area. <br /> •AII roof drains must be directed away from the system <br /> •AII tanks must be tested for watertightness and have a water-tight riser to the ground surface.Twenty-inch <br /> minimum diameter if less than 36-in deep.Thirty-inch minimum diameter if greater than 36-in deep. Maintain <br /> access to septic tank for pumping and service. <br /> •Meet all required setbacks <br /> •The system must be installed in the area approved during the site evaluation and in accordance with the <br /> construction plan approved by the agent, including any changes made by the agent. <br /> •The pump and alarm must be wired oh separate circuits in the control panel. Pump wiring must comply with <br /> applicable building,electrical,or other codes.An electrical permit and inspection from the Department of <br /> Consumer and Business Services, Building Codes Division,or the municipality with jurisdiction, is required for <br /> pump wiring installation. <br /> •Install the pump and system components in accordance with the approved pump curve and specifications. <br /> •An anti-buoyancy device is required for the septic tank(s)and must be installed as per the manufacturer <br /> installation guidelines. <br /> •A minimum 18-gauge,green jacketed tracer wire orgreen color-coded metallic tape must be placed on top of <br /> the effluent sewer or pressure transport pipe from tank to drainfield. <br /> 8/22/22:8:16:51AM• ONS_OnsitePermitpr <br />
The URL can be used to link to this page
Your browser does not support the video tag.