My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
11857422
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
20-XXXXXX
>
11857422
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/5/2023 2:07:59 PM
Creation date
9/20/2023 2:05:16 PM
Metadata
Fields
Template:
Permits
Permit Address
9308 SILVER FALLS HWY SE
Permit City
Aumsville
Permit Number
555-20-008588-PRMT-01
Parcel Number
082W13DA01400
Permit Type
Septic
Permit Doc Type
Permit Document
Status
Ready to Film
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Oregon Department of Environmental Quality <br /> Septic Tank was ppumped previosly by another company <br /> • The septic tank material is: <br /> E Concrete <br /> E6 Steel <br /> ❑ Plastic <br /> ❑ Fiberglass <br /> ® Other(explain) <br /> ❑ Unknown <br /> • Is the septic tank accessible? ®Yes ❑No <br /> • Septic tank volume in gallons <br /> • Tank volume determined by:Check all that apply,add comments below as needed <br /> ❑Permit Records❑Measured❑Stamped on Tank❑Other <br /> • Septic tank risers are at ground level ['Yes ❑No <br /> P <br /> • Tank appears to be free from defects,leaking and signs of deterioration['Yes ®No <br /> If you answered"No,"please describe the condition of the septic tank below.For example, <br /> evidence of gas corrosion,cracks,leaks,etc. <br /> • Septic tank lid(s)is intact ❑Yes ❑No <br /> • Septic tank baffles are intact:Inlet ❑Yes ❑No Outlet ['Yes ❑No <br /> • Baffle material-Inlet❑Plastic rIConcrete ❑Metal Outlet rPlastic [Concrete [Metal <br /> Effluent filter is present ❑Yes ❑No <br /> • Effluent filter is free of debris ['Yes ❑No ❑Not Applicable <br /> • Liquid level in tank relative to invert of outlet ❑At ['Above ['Below <br /> If above or below invert outlet,please explain: <br /> • Scum layer (inches) Sludge layer (inches) <br /> • Scum and Sludge layer more than 35%of the total tank volume ❑Yes ❑No <br /> Indicate where sludge measured from:['Inlet ['Middle ['Outlet <br /> • Additional Comments: <br /> 4. Dosing tank/Pump Basin <br /> Dosing tanks use a pump to send effluent to a treatment unit or a soil absorption field. <br /> • The septic system has a dosing tank ['Yes ®No <br /> (If"No,"skip the rest of section 4) <br /> • At the time of this evaluation the power was on to test the pump(s):['Yes ❑No <br /> Page 3 of 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.