Laserfiche WebLink
Septic Site Evaluation 555-23-005539-EVAL Page 2 of 2 <br /> Date fssued,09/0112023!;i;q*LAzte:,t0Z a H x 1 <br /> , ��.� ...< ���3f � �*� <br /> Appiication st tus SIt•�EvalUaf)on`�Appraved <br /> ,4epr 5 E ' �kt <br /> sx . .b �, r � °�s7sla,�� r� � � ra ,� a A a; � _<..x <br /> Work descriptran-'SE MORE 3 BDRMiSFDI M V ' a e 4 5M , t*"s � <br /> k � '".s t sV <br /> p k <br /> .,.,� ...,. .. �,. _ ..,, ..,, ..,.,.,........ .. ......... ........ <br /> Groundwater interceptor-amount of drain media: 63 in. 63 in. <br /> Groundwater interceptor depth: 63 in. 63 in. <br /> Drainfield type: Standard Standard <br /> Drainfield sizing: 150 linear ft/150 gal. 150 linear ft/150 gal. <br /> Pump to drainfield required: Yes Yes <br /> Other special requirement: Curtain drain will be required, Installed at a Curtain drain will be required, Installed at a <br /> depth of 63 inches deep with gravel to the depth of 63 inches deep with gravel to the <br /> surface,and a 12 inch berm on the down surface,and a 12 inch berm on the down hill <br /> hill side of the curtain drain trenc,filter side of the curtain drain trenc,filter fabric <br /> fabric needs to be laid 6 inches below needs to be laid 6 inches below surface and <br /> surface and again at 57 inches again at 57 inches <br /> THIS IS NOT YOUR PERMIT.A Construction/Installation permit is required before you construct your system.Please contact <br /> this office when you are ready to apply for a construction/installation permit.We cannot sign off on any Building Codes forms <br /> until we issue your permit. <br /> This site approval runs with the land and will automatically benefit subsequent owners.This site approval is valid until the <br /> approved system is constructed under a DEQ construction permit or unless the site is altered without approval from this office. <br /> Alterations/excavations/lot line adjustments made to the site,or placement of wells or utilities,etc., may invalidate this approval <br /> If you disagree with the decision of this report,you may apply for a site evaluation report review. The application for a site <br /> evaluation report review must be submitted to DEQ in writing within 60 days after the site evaluation report issue date and must <br /> include the site evaluation review fee in OAR 340-071-0140 Table 9A. A senior DEQ staff person will be assigned the site <br /> evaluation report review application. <br /> You may apply for a variance to the onsite wastewater treatment system rules. The variance application must include a copy of <br /> the site evaluation report, plans and specifications for the proposed system,specify the rule(s)to which a variance is being <br /> requested,demonstrate the variance is warranted,and include the variance fee in OAR 340-071-140 Table 9C. A variance may <br /> only be granted if the variance officer determines that strict compliance with a rule is inappropriate or special physical conditions <br /> render strict compliance unreasonable,burdensome or impractical. A senior DEQ variance officer will be assigned the variance <br /> application. <br /> Kimberlee Aldrich Onsite Wastewater Specialist 2 9/1/23 <br /> • <br /> CALL BEFORE YOU DIG...ITS THE LAW <br /> ATTENTION:Oregon law requires you to follow rules adopted by the Oregon Utility Notification Center. Those rules are set forth by Oregon Administration Rules. You may obtain <br /> copies of the rules by calling the center.(Note:The telephone number for the Oregon Utility Notification Center is 1-800-332-2344.) <br /> 9/1/23:9:06:56AM Page 2 of 2 ONS_OnsiteEvaluation_pr <br />