Laserfiche WebLink
• <br /> Infiltrator IM and TW-Series. I `� NOVEMBER 2013 <br /> 0 <br /> Tarrk-Buoyancy an�c. Con r�of-Guidance � , r v� r FELTRaTo-R® <br /> oY Y <br /> tanks i <br /> Before you=Begin' Concrete Deadmen Anchors <br /> This document presents recommended buoyancy control methods for Recommended concrete deadmen anchors include filled plastic half pipe, <br /> Infiltrator Systems Inc;s(Infiltrator's)IM-and TW-Series tanks.Tank precast parking bumpers and traffic barriers,and poured blocks.The <br /> • buoyancy control methods must be implemented according to state weight of the deadmen anchors combined with the weight of soil above <br /> and/or local regulations,which may supersede the guidelines in this them provides buoyancy control when properly secured.Deadmen anchors <br /> document.If unsure of the requirements for a particular site,contact are placed at the bottom of the tank excavation on opposite sides of the <br /> the local health department or permitting authority. tank.The deadmen anchors are fastened to each other with tie-down <br /> straps placed up and over the tank at the locations specified for each tank <br /> model(see Figure 5). <br /> This document provides procedures to determine if tank buoyancy control <br /> is required based on site conditions.Please obtain the following information 15 in[315 mm]to <br /> to determine if control is necessary and what methods are applicable: 18 in[450 mm] Concrete-filled plastic half pipe <br /> • Infiltrator tank model Use Schedule 40 PVC plastic pipe having a <br /> minimum inside diameter of 15 inches(375 mm) <br /> • Maximum height of water outside the tank and above the tank bottom or HDPE corrugated pipe having a minimum <br /> elevation inside diameter of 18 inches(450 mm)cut in half <br /> • Depth of soil cover over the tank top r lengthwise.Fill with concrete having a minimum <br /> Once tank buoyancy control measures are determined to be required and o o unit weight of 145 lbs/ft3(2.32 metric .tons/m) <br /> a method has been selected and implemented,refer to Infiltrator IM-and 1/2-inch(1d with three equallyrsteel spaced 40-grade,is <br /> 1/2-inch(13 mm)diameter bars.Weight is 61 <br /> TW-Series Tank Installation Instructions and Riser Connection Guidance lbs/ft(91 kg/m)minimum. <br /> documents,as applicable,for completing the installation. <br /> Steel Rebar <br /> How to Use this Document 1 <br /> Concrete parking bumper 6 in i <br /> 1. Become familiar with the descriptions In the Compatible Devices and Use commercially available steel-reinforced [150 mnij)' -.i .q <br /> Products section. parking bumpers with typical dimensions of 1 <br /> 2.Verify the water level outside the tank is below the outlet pipe 12 inches wide by 6 inches high(300 mm x 150 1 12 in <br /> saddle height using Step 1,Tables 1 and 2,and Figure 1. mm).Weight is 58 lbs/foot(86 kg/m)minimum. [300 mm] <br /> 3.Determine if buoyancy control is required using Step 1,Table 2. <br /> If buoyancy control is required,proceed to Step 2. Concrete traffic barer <br /> 2.Use the respective table for the tank model from Step 2,Table 3 to Use commercially available steel-reinforced <br /> determine the appropriate buoyancy control methods for the site I concrete traffic barrier or equivalent.Typical <br /> conditions. i dimensions include a 24-inch-wide base <br /> y tapering to a 6-inch-wide top,with a height <br /> 5.Once a preferred'buoyancy control method is selected,follow the 32 in1.4 of approximately <br /> procedures for implementation provided in Step 3. 32 inches 600 mm x 150 mm x 800 mm.Weight <br /> [800;mm] G ( ) g <br /> 3 is 390 lbs/foot(580 kg/m)minimum. <br /> Parts and Supplies. . , Poured Blocks <br /> The parts and supplies necessary are to be purchased separately from the " . Concrete precasters can pour blocks of <br /> tank.All parts and supplies are either commercially available or available i ° ° <br /> t ' < A various dimensions and weights.Blocks are <br /> through Infiltrator's network of tank distributors.Some parts may require ' ' <br /> often an affordable option if they satisfy the <br /> fabrication on site using common construction practices. ± 24 in weight requirements for use as buoyancy <br /> [600 mm] control(see Table 3 and the Supplemental - <br /> Compatible Devices and Products Force section of Step 2 for more information). <br /> Infiltrator tanks are compatible with the following products for buoyancy <br /> control: Helical Anchors 5,1 U^TUR,.. <br /> • Tie-down straps:high-tensile-strength 10,000 Ib(4,500 kg) ChanceTM No-Wrench Screw Anchors with <br /> pwebbing, R9 rROF a 6-inch(150 mm)diameter flight,Class 7, f minimum capacity,nylon or polyester,with corrosion-resistant hardware. `s/ <br /> or equal.These anchors rely on the shear .Cr] N 4 �,A <br /> • Concrete deadmen anchors:concrete-filled plastic half pipe,precast strength of the soil combined with the wei <br /> parking bumper,precast traffic barrier,or poured block. of the soil above the anchor flight to provi= ! ` 13a7$PE 43 l <br /> • TM holding strength.Proper installation is to 44,Helical anchors:ChanceTM No-Wrench Screw Anchors with minimum •Z• •`• <br /> 4 feet(1.2 m)below the bottom of the tank ��[['�"- <br /> 6-inch(150 mm)diameter,Class 7 or equal. fi`" ' f <br /> excavation and to within 5°of alignment ,.,,,.' EC tp i' �` <br /> with the webbing load.Determine the ''f`' + � <br /> Tie-Down Straps proper locations for anchor installation to 4 1' .k�s <br /> Straps are commercially available in varying �. ensure that tie-down straps will be aligned ,E.L;t" <br /> D =. properly for each tank model(see Step '* <br /> lengths and with assorted hardware and y;i.. --,. 3:Implementation),and follow anchor <br /> tightening options.Nylon or polyester manufacturer installation instructions. EXPIR (ON D, : 12-3t-20) <br /> strapping with minimum 10,000 lb(4,500 kg)capacity is required for <br /> buoyancy control use with Infiltrator tanks.Place straps up and over the - <br /> tank at specified locations only(see Figure 5).Tighten straps snugly with <br /> a ratchet or turnbuckle system to remove all slack and slightly pre-load Typical working torque: <br /> the system.All connections,fittings,and hardware must be corrosion 1" Rod 400 ft.Ibs..(1, N.m) <br /> resistant or coated with epoxy or other corrosion-resistant materials to Rod 1,000 ft.Ibs 1356 N.m) p *. <br /> inhibit deterioration in the subsurface environment.Consider encapsulating <br /> 1'h"Rod 2,300 ft.lbs.(3,118 N.m) ° '' <br /> such components in heat-shrink tubing or painting on additional corrosion- <br /> resistant coatings prior to burial. <br /> Contact Infiltrator Systems'Technical Services Department for assistance at 1-800-221-4436. <br />