sech-J1-‘4"e/- 14v,,joj <br /> V U l' boy <br /> Step 1—Determine Need for Buoyancy Control AVTable 1:Maximum Allowable Subsurface <br /> Required information:the maximum height of water outsi the tank and above the tank bottom AND Water Elevation <br /> the depth of soil cover above the tank top.Tank buoys control may be required if the water level <br /> outside the-tanlchas the-potentiarto-rise 30 inche 0 mm)or more above th bot om ofth k, <br /> AND less than 12 inches(300 mm)of soil c is to be placed as backfill over the tank top°Otherwise, verllcel fytstance soMe <br /> 9owabie taterE�'ev>aeon Outside at Tank•' <br /> no buoyancy control is required., <br /> Tank.R4odei A=From1opofTank, B Tankallselb <br /> Allowable Subsurface Water Elevation IM-Series' 13"(330 mm) 43"(1,075 mm) <br /> Groundwater elevation,groundwater table,and water table are terms for the subsurface condition <br /> where water is held in the subsurface soil pores or rock.The seasonal high groundwater elevation TW-Series= 11"(280.mm) 39"(975 mm) <br /> represents the highest point the water table has the potential to reach at any time of the year,and <br /> is not necessarily the level at which groundwater may be observed seeping from the soil at the time 1.IM-Series tanks include the IM-540,IM-1060 <br /> of tank installation.In general,a qualified soil evaluator or engineer can estimate the seasonal high and IM-1530. <br /> groundwater elevation from careful examination of the soil profile. • 2.TW-Series tanks include the TW-1250 and TW-1500. <br /> Under certain conditions,a perched water table may be present in the subsurface.A perched water <br /> table occurs where there is an impermeable or low-permeability soil that causes water to be present <br /> in the soil pores above the main water table.A perched water table elevation may exceed the seasonal Figure 1:Water Elevation <br /> high elevation of the main water table.The vertical position of the tank must account for both the <br /> seasonal high groundwater table and any existing or future perched water table condition.Verify that <br /> the subsurface water level will not exceed the height of the outlet pipe saddle of the tank,as 18"(450 mm)Or Less.Soil Backfill Above Tank Top <br /> show in Tables 1 and 2,and Figure 1. <br /> Table 2 Instructions Top of Tank <br /> 1. In the left-hand column of Table 2,locate the row corresponding to the height of the water elevation �i n`N A(Table 1) <br /> outside the tank and above the tank bottom(Parameter I)for the site conditions.See Figure 2. ——t !"I =` <br /> 2.Follow that row to the right until reaching the column corresponding to the depth of soil cover proposed Seasonal HighWig I <br /> above the tank top(Parameter II).See Figure 2. Groundwater'(600 Higher l B(Table <br /> Thano 2T"(600 mm) 1) <br /> 3. If the tank model is described in that cell,then buoyancy control is required as described for the tank Above Tank Bottom <br /> (proceed to Step 2).If the tank model is not listed in that cell,then no buoyancy control is required. ItKM <br /> / <br /> 4.The tank shall not be installed where the water level outside the tank exceeds the height of the outlet Maximum Allowable Tank Base <br /> pipe saddle.Follow guidelines in Tables 1 and 2. Water Position <br /> Table 2:Infiltrator tank models' and conditions requiring buoyancy control • Corresponds e nt rtrtlet <br /> 3 ; T Y PipeSaddle Invert <br /> Parameter II Soil cover depth above tank top' <br /> Parameter i , <br /> Water height above,tankbottom <br /> Figure 2: Buoyancy Control Parameters <br /> . <br /> 6 in(150 mm)to Above 12 in <br /> 12 in(300 mm) (300mm) Parameter II <br /> Depth Of Soil Cover <br /> t �i(kbove outlet pipe saddle 3` Do not install Do not install Above Top Of Tank <br /> (900 mm)to outlet pipe saddle 0:, ,, All models None <br /> All models except IM- <br /> 3 30"(750 mm)to 36"(900 mm)' None <br /> 540 and IM-1060 # Arlin <br /> tit <br /> 4 L,eliathen30". mm) "Ve, .`' None None Parameter rtt <br /> Water Height <br /> Above Tan Bottom: <br /> NOTES: <br /> sandS�=- ..d <br /> 1.Infiltrator tank models include:IM-540,IM-1060,TW-1250,TW-1500 and IM-1530. <br /> 2.Water height corresponds to seasonal high groundwater elevation or perched water elevation measured from bottom-of-tank elevation. <br /> 3.Minimum 6 inches soil cover backfill required above all Infiltrator tanks. <br /> 4.The tank shall not be installed where the water level outside the tank exceeds the height of the outlet pipe saddle.Follow Table 1 guidelines. <br /> Design Example <br /> A contractor plans to install an IM-1060 tank where the water level outside the tank Table 2:Infiltrator tank models and conditions requiring <br /> has the potential to rise to 37 inches(940 mm)above the tank bottom(Parameter I), buoyancy control <br /> and the design plan calls for 8 inches(200 mm)of soil cover above the top of the tank <br /> Parameter ll:Soil cover depth above tank top(Parameter II)° In Step 1,Table 2,a 37-inch(940-mm)exterior water height corresponds - <br /> to row 2(36 inches[900 mm]to outlet pipe saddle)under Parameter 1. The 8-inch w t,�ghtay.tankuatmm e <br /> (200-mm)soil cover corresponds to column A(6 inches[150 mm]to 12 inches[300 mm]) " sa ' +sttt Above 12)n' <br /> (300 mm) <br /> under Parameter II in Table 2. At the intersection of Parameter I,row 2 and Parameter <br /> II,column A,Cell 2A indicates"All models",meaning all tank models,including the 1 Abov autietpipoead , „ ¢ g Do not install <br /> IM=1060,require buoyancy control under these conditions Referring to Step 2,Table 3, %' <br /> under the IM-1060 heading,Case 1-would apply for 37 inches(940 mm)of water above z' " tom' <br /> 2�. Alt models, None the bottom of tank and 8 inches(200 mm)of soil cover. Available options are as follows . <br /> o - <br /> (see specific strapping and construction information under Step 3): <br /> 30In(750 mm)to All models except <br /> •If concrete block is specified to anchor the IM-1060,the total combined minimum 38 in(900 mm) IM-540 and IM-1060 Nona <br /> weight of blocks placed on each side of the tank shall be 2,700 pounds(1,225 kg). —" <br /> The size and shape can be determined by locally available materials.Connect using 4 Leas than 30 in(750 mm) None None <br /> two straps. <br /> •For concrete-filled half pipe and concrete traffic barrier,the minimum length on each <br /> side of the tank would be 4.2 feet(1.3 m),while at least 4.5 feet(1.4 m)of concrete <br /> parking bumper would be required. These controls would be connected with two <br /> straps,ensuring that the control extends a minimum of 6 inches(150 mm)beyond the <br /> strap positions(see Figure 3). <br /> •If helical anchors were selected,a minimum of two 6-inch(150 mm)diameter anchors <br /> per side of tank(4 total)would be installed using two straps. <br /> • <br /> Contact Infiltrator Systems'Technical Services Department for assistance at 1-800-221-4436. <br />