Laserfiche WebLink
Septic Permit 555-�2+j0-0}0'9082-PRMT Page 4 of 5 <br /> Date s 41 cate Issu f 06 • <br /> 1202 % Y <br /> Workbescnptton FIRE RES MAJ I tEPAIRR REPLY$BDRM RES NEW LQCAT1O a ' <br /> m.. . ,+ c - . 3'v,_....... c�w�.. .. .� <br /> Linear Feet/150 gal <br /> Drainfield Required <br /> 188 <br /> Linear Feet • <br /> Absorption Field Depth <br /> 18" Min; 24" Max <br /> Additional Conditions of this installation permit <br /> •Both the initial and replacement disposal areas are to be protected from traffic, livestock and <br /> farming activities, development or other potential disturbance of natural soil conditions. <br /> •The area must not be subjected to excessive saturation due to, but not limited to, artificial <br /> drainage of ground surfaces, roads, driveways and building down spouts. <br /> •This approval is given on the basis that the parcel described above will not be further partitioned or <br /> subdivided. <br /> •Placement of a well within 100 feet of the approved areas may invalidate this approval. <br /> •The system must be installed by the property owner or a licensed sewage disposal business <br /> (installer) <br /> •All tanks must be tested for water-tightness and have a water-tight riser to the ground surface. <br /> Twenty- inch minimum diameter if less than 36-in deep (thirty-inch minimum diameter if greater than <br /> 36-in deep). <br /> •Maintain access to septic tank for pumping and service. <br /> •Meet all required setbacks <br /> •The system must be installed in the area approved during the site evaluation and in accordance <br /> with the construction plan approved-by the agent, including any changes made by the agent. <br /> •All work is to conform to OAR 340, Division 71 and 73. Make no changes in system location or <br /> specifications without approval by the agent. <br /> •For product approval information and manufacturer installation requirements see DEQ website at: <br /> http://www.oregon.gov/deq/Residential/Pages/Onsite.aspx <br /> •A minimum 18-gauge, green-jacketed tracer wire or green color-coded metallic tape must be <br /> placed on top of the effluent sewer or pressure transport pipe from tank to drainfield. <br /> •Effluent sewer must extend at least 5 feet beyond the septic tank before connecting to the <br /> distribution unit. It must be installed with a minimum fall of 4 inches per 100 feet and at least 2 inches <br /> of fall from one end of the pipe to the other. In addition, there must be a minimum difference of 8 <br /> inches between the invert of the septic tank outlet and either the invert of the header to the <br /> distribution pipe of the highest lateral in a serial distribution field or the invert of the header pipe to the <br /> distribution pipes of an equal distribution absorption field <br /> •Each drainfield trench must be level within a tolerance of plus or minus 1-inch. <br /> 6/13/22:7:16:12AM ONS_OnsiteCSC_pr <br />