My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
11190191
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
21-XXXXXX
>
11190191
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/10/2022 3:07:11 PM
Creation date
8/11/2022 4:44:48 PM
Metadata
Fields
Template:
Permits
Permit Address
145 HOWE ST E
Permit City
Detroit
Permit Number
555-21-006262-PRMT
Parcel Number
105E01DC05900
Permit Type
Septic
Permit Doc Type
Permit Document
Status
Ready to Film
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Page 3 <br /> 1003T-GEO lowing a sand filter in lieu of the chamber described in OAR <br /> NATIVE BACKFILL ESTABLISH <br /> 6"MIN.COVER VEGETATIVE Chapter 340 Division 71. Construction shall conform to all <br /> OR PER CODE,- COVER requirements described within Chapter 340 Division 71 with <br /> the following modifications: <br /> . 0PIPE PERFORATED a.The perforated pressure piping shall be placed <br /> FILTER FABRIC within the 4-inch diameter perforated polyethylene <br /> 15" '4 r1a piping with orifices at the 12 o'clock position. <br /> 10"EZflow b. Because the top of the bundle will be at the <br /> 24"MIN. BUNDLE(TYP.) capping TRENCH ground round surface, a ca in fill shall be used <br /> WIDTH to cover the installation.Soil texture from the surface <br /> Figure 3 <br /> to the trench bottom shall not be finer than silty clay <br /> trench. For example, if the sizing for a 2-foot gravel trench loam. <br /> requires 100-linear feet of trench, the 1003T system will be <br /> sized at 100-linear feet. See the Oregon Chamber Design and Installation Manual for ad- <br /> ditional options and information. <br /> The Capping Fill System <br /> The 1201 P/1201 P-GEO Seepage Trench System <br /> The 1201 P-GEO drainfield system consists of one, 12-inch 10045/1004S-GEO, 1204S/1204S-GEO <br /> diameter bundle installed in a 12-inch wide trench.See figure Both the 10-inch and 12-inch diameter bundles may be in- <br /> 1 for example configuration. stalled in seepage trenches in lieu of drain media. Four or <br /> more bundles can be placed in a 24-inch wide trench.At least <br /> The 1202H one of the top bundles shall contain perforated piping. Serial <br /> The 1202H drainfield system may also be installed in a hori- distribution methods limit the maximum effluent depth to no <br /> zontal configuration in a capping fill system, within a 24-inch more than 6-inches higher than the invert level of the perfo- <br /> wide trench that is a minimum of 12-inches deep. See figure rated piping within the higher trenches.The minimum backfill <br /> 2 for example configuration. depth is 6-inches when equal distribution methods are used, <br /> and 12-inches with serial distribution methods. See Figure 5 <br /> The 1003T for example configuration. - -- <br /> The 1003T drainfield system may also be installed in a cap- 1204S-GEO <br /> ping fill system.The 1003T in the horizontal configuration is <br /> installed in a 30-inch wide trench that is a minimum of 12- ESTABLISH �,* <br /> VEGETATIVE COVER <br /> inches deep.The 1003T triangular configuration is installed in ki , , r, .lE'<��\`,.,, i i,,,; <br /> a 24-inch wide trench that is a minimum of 17-inches deep, NATIVE 6/NCl/TILL 6"MIN. ,:';;::;,:,,>:?';;. `«.:`,�:°;!' <br /> COVER OR PER CODE ':.'• FILTER FABRIC ?, <br /> with the cap placed in accordance with the requirements of ( ri :• <br /> OAR Chapter 340 Division 71.See Figure 3 for example con- ( `.. 4"PERFORATED PIPE j <br /> figuration. i 24" ® i' <br /> r' 11t1 12"EZflow <br /> `; f .. ', BUNDLE(TYP.) ,/ <br /> Conventional Sand Filter System Using Gravelless ;i: ;. a,ti �/ <br /> Absorption'Trenches-The 1001 P/1001 P-GEO tL -1 J 1H <br /> =i"\\ 24"MIN. <br /> The 1001 P/1001 P-GEO drainfield system (10-inch diameter TRENCH—I <br /> bundles containing 4-inch diameter perforated polyethylene WIDTH <br /> Figure 5,,.-0 <br /> piping, placed end to end within the trench) may be used fol- <br /> 1001P-GEO Steep Slope Systems <br /> I00IA/1001A-GEO, 1001 P/1001 P-GEO <br /> NATIVE ESTABLISH 1201A/1201A-GEO, 1201 P/1201 P-GEO <br /> BACKFILL VEGETATIVE Both the 10-inch and 12-inch diameter bundles maybe <br /> 4"MIN. COVER <br /> CAPPING FILL used within seepage trenches in a steep slope system in <br /> .};;;,, ;,i,,; FILTER FABRIC lieu of drain media. Four bundles can be placed in a 24-inch <br /> wide trench. At least one of the top bundles shall contain <br /> the perforated piping.Serial distribution methods limit the <br /> 10" ""O'.`i;'i . 4"PERFORATED PIPE <br /> maximum effluent depth to no more than 6,inches higher <br /> i than the invert level of the perforated piping with the higher <br /> L-''I, trenches.GEO product can only be used at the top of the <br /> 10"MIN. ~'''�'%C=BUNDLE(TYP.) configuration.See Figure 5 for example configuration. <br /> TRENCH <br /> WIDTH <br /> Figure 4 <br /> Contact Infiltrator Systems'Technical Services Department for assistance at 1-800-221-4436 <br />
The URL can be used to link to this page
Your browser does not support the video tag.