My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
11190172
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
20-XXXXXX
>
11190172
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/18/2022 1:43:53 PM
Creation date
8/11/2022 4:44:20 PM
Metadata
Fields
Template:
Permits
Permit Address
997 IVA LN NE
Permit City
Salem
Permit Number
555-20-008243-PRMT
Parcel Number
072W20D 02301
Permit Type
Septic
Permit Doc Type
Permit Document
Status
Ready to Film
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Septic Permit 555-20-008243-PRMT Page 2 of 3 <br /> Date Cer4frcate Issued0:7/19/2022 <br /> Work Descrrptra r NEW INSTALL �W BDRM SFD <br /> d�9 fr <br /> Condrtwns of Approval -` <br /> •This permit is for the installation of an Alternative Treatment Technology(ATT) system and is to be installed by a <br /> person certified by the system manufacturer in accordance with OAR 340-071-0600 and 0650. See Alternative <br /> Treatment Technology rules at OAR 340-071-0345. <br /> •In addition to the As-Built and Materials List, a Start-Up checklist from the ATT maintenance provider is required to <br /> Final this permit. <br /> •The owner of an ATT system must maintain a contract with a maintenance provider certified by the manufacturer <br /> to inspect, adjust and maintain the onsite system. The maintenance provider must submit an annual report and <br /> annual evaluation fee. <br /> •Gravelless absorption method rules at OAR 340-071-0290 (6). Pressurized distribution required w/distribution <br /> piping perforated with 1/8 inch diameter orifices on maximum 2-foot centers at the 12 o'clock position and at least a <br /> 2-foot residual head at the distal orifice. <br /> -Initial and Replacement Areas—Protection: The installed subsurface absorption field and designated <br /> replacement areas must be protected and kept free of development such as roadways, covering with asphalt or <br /> concrete, filling, cutting, or other soil modifications. <br /> •Dry soil installation only(June 1 —October 1 unless otherwise authorized by the agent). <br /> •All tanks must be tested for watertightness and have a water-tight riser to the ground surface.Twenty- inch <br /> minimum diameter if less than 36-in deep. Thirty-inch minimum diameter if greater than 36-in deep. Maintain access <br /> to septic tank for pumping and service. <br /> •The system must be installed in the area approved during the site evaluation and in accordance with the <br /> construction plan approved by the agent, including any changes made by the agent. <br /> •The pump and alarm must be wired on separate circuits in the control panel. Pump wiring must comply with <br /> applicable building, electrical, or other codes. An electrical permit and inspection from the Department of Consumer <br /> and Business Services, Building Codes Division, or the municipality with jurisdiction, is required for pump wiring <br /> installation. <br /> •An anti-buoyancy device is required for the septic tank(s)and must be installed as per the manufacturer <br /> installation guidelines. <br /> •A minimum 18-gauge, green jacketed tracer wire or green color-coded metallic tape must be placed on top of the <br /> effluent sewer or pressure transport pipe from tank to drainfield. <br /> Installation of this onsite wastewater treatment system has been determined to comply with the applicable requirements in <br /> Oregon Administrative Rules Chapter 340, Divisions 071 and 073 and the Conditions of Approval above. <br /> 1. In accordance with Oregon Revised Statute 454,665,this Certificate of Satisfactory Completion is issued as evidence of <br /> satisfactory completion of an onsite wastewater treatment system at the location identified above. <br /> 2. Issuance of this Certificate does not constitute a warranty or guarantee that this onsite wastewater treatment system will <br /> function indefinitely without failure.Conditions imposed as permit requirements continue for the life of the system. <br /> 3.The area of the initial and the identified replacement area must not be subjected to activity that is likely to adversely affect <br /> the soil or the functioning of the system.Such activities may include, but are not limited to,vehicular traffic, livestock, <br /> covering the area with asphalt or concrete,filling,cutting,or other soil modification activities. <br /> 4.This onsite wastewater treatment system that be connected to the facility referenced herein within 5 years of the issuance <br /> of this Certificate of Satisfactory Completion (CSC)or rules for authorization notices, alteration permits,or <br /> construction-installation permits as outlined in OAR 340-071-0160, 340-071-0205,or 340-071-0210 apply,including payment <br /> of an additional fee. <br /> 5.This system must operate in compliance with OAR Chapter 340, Division 071 and must not create a public health hazard <br /> or pollute public waters. <br /> 6. Unless otherwise required by the agent,the system installer must backfill (cover)this system within 10 days after the <br /> issuance of this Certificate of Satisfactory Completion. <br />� 4 <br /> 7/19/22:2:34:28PM ONS_OnsiteCSC_pr <br />
The URL can be used to link to this page
Your browser does not support the video tag.