Laserfiche WebLink
Septic Authorization 555-20-009347-AUTH Page 2 of 2 <br /> Dated ued:6L18/21t 3• Date fir ng,6/8/22 s- r* f'' ;�, Vr :=� ' ` ' <br /> Work Descrip+on -14 FIRE AUTI�f BDRt�SFD TO RERL1 BDRM sFD � f z A_¢ ,; s' a�` °�� <br /> a ,i s '};# W ',} r a "J t. � , 4th <br /> 4 . ' '� �r�, s$ •?�4 a! ,' 'F•p b,'�a. :i 4. i • t r''� '3 " 5 4 '3' c.'�t J �5 s -"f 'r�. ' "d-'-.. :y' k .1 -• <br /> `F'?:;' <br /> Conditions of Approval: <br /> THIS SYSTEM IS AUTHORIZED PER OAR 340-071-0205(4)WITH NO INCREASE IN FLOW. <br /> This septic system previously had no records,the system was pumped by Farmer's septic on December 23,2020,and located <br /> by Action Drain on November 11,2020.The tank was found to be leaking,the distribution box was damaged by root intrusion <br /> and 116'feet of drain line was found.This Authorization is being issued following a Certificate of Satisfactory completion for <br /> replacement of the septic tank and distribution box.This was issued on June 15,2021. <br /> There is no increase in flow to the system as there was a 1 bedroom onsite before the fire and will be replaced with a 1 <br /> bedroom.This system meets standards set by the DEQ under OAR 340-071-0205(4)authorization rule allowing for connection <br /> of a replacement dwelling with no increase in flow.This authorization notice is APPROVED. <br /> THE APPROVED SEPTIC SYSTEM AREA MUST BE PROTECTED from any vehicular traffic including construction vehicles, <br /> livestock activities.Other activities such as logging, excavating or filling,driveway placement or any similar activities may also <br /> damage the soil in the area and adversely affect the septic system approval. The areas of the initial septic system and the future <br /> repair system must both be protected. <br /> The septic tank should be pumped and inspected by a licensed septic tank pumping service approximately every five(5)years. <br /> The septic tank is a reservoir for the solid materials in the sewage waste stream. Excessive accumulation of these solid <br /> materials in the septic tank will cause the solids to wash out of the tank and into the drainfield. This will cause irreversible <br /> damage to the drainfield and will eventually lead to a system failure. <br /> Note:This Notice does not guarantee satisfactory or continuous operation of the sewage system.Should the system fail,a repair <br /> permit from DEQ is required. <br /> If you disagree with this report,you have the right to apply for an authorization notice denial review.The application for review <br /> must be submitted in writing within 45 days of the report issuance and be accompanied by the review fee in OAR <br /> 340-071-0140(3),Table 9C and any additional information DEQ needs to complete the review. <br /> You may apply for a variance to the onsite wastewater treatment system rules. The variance application must include a copy of <br /> the site evaluation report,plans and specifications for the proposed system,specify the rule(s)to which a variance is being <br /> requested,demonstrate the variance is warranted,and include the variance fee in OAR 340-071-140 Table 9C. A variance may <br /> only be granted if the variance officer determines that strict compliance with a rule is inappropriate or special physical conditions <br /> render strict compliance unreasonable, burdensome or impractical. A senior DEQ variance officer will be assigned the variance <br /> application. <br /> Robert Goof in / Onsite Wastewater Specialist 2 6/18/21 <br /> e•—• <br /> (-1/4 ^5—(c),)-0C0Y-° WW2( <br /> 6/18/21:3:08:16PM Page 2 of 2 ONS_OnsiteAuthorizationjr <br />