My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10512762
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
21-XXXXXX
>
10512762
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/29/2021 10:03:13 AM
Creation date
6/25/2021 2:20:26 PM
Metadata
Fields
Template:
Permits
Permit Address
23405 SALMONBERRY WAY SE
Permit City
LYONS
Permit Number
555-21-003530-AUTH
Parcel Number
092E17BD00301
Permit Type
Authorization
Permit Doc Type
Permit Document
Status
Ready to Film
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Oregon Department of Environmental Quality <br /> * The septic tank material is: <br /> FIConcrete <br /> Steel <br /> Plastic <br /> Fiberglass <br /> Other(explain) <br /> Unknown <br /> * Is the septic tank accessible? x Yes No <br /> * Septic tank volume in gallons 1,000 <br /> * Tank volume determined by:Check all that apply,add comments below as needed <br /> x Permit Records x Measured I IStamped on Tank Other <br /> * Septic tank risers are at ground level Yes 51 I No <br /> * Tank appears to be free from defects,leaking and signs of deterioration Yes I x No <br /> If you answered"No,"please describe the condition of the septic tank below. For example, <br /> I•ence of gas corrosi•• - • , ea—,-" <br /> TANK IS HALF FULL AND - EAKING AT CENTER SEAM. <br /> * Septic tank lid(s)is intact x Yes No <br /> * Septic tank baffles are intact: Inlet x Yes No Outlet x Yes No <br /> * Baffle material-Inlet Plastic []Concrete Metal <br /> Outlet Plastic Concrete X I Metal <br /> * Effluent filter is present 17 Yes I x I No <br /> * Effluent filter is free of debris Yes No x Not applicable <br /> * Liquid level in tank relative to invert of outlet raiAt bove x I Below <br /> If above or below invert outlet,please explain: NK IS LEAKING. <br /> * Scum layer 3 (inches) Slud a (inches) <br /> * Scum and Sludge layer more than 35%of the total tank volume Yes x No <br /> Indicate where sludge measured from: Inlet Middle x Outlet <br /> * Additional comments: <br /> 4. Dosing tank/Pump Basin <br /> Dosing tanks use a pump to send effluent to a treatment unit or soil absorption field. <br /> * The septic system has a dosing tank I Yes x No <br /> (If"No,"skip the rest of section 4) <br /> * At the time of this evaluation the power was on to test the pump(s): Yes No <br /> Page 3 of 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.