10512290
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
21-XXXXXX
>
10512290
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/25/2021 8:00:13 PM
Creation date
6/25/2021 11:25:46 AM
Metadata
Fields
Template:
Permits
Permit Address
34020 RAILROAD AVE SE
Permit City
GATES
Permit Number
555-21-003820-AUTH
Parcel Number
094E30 01600
Permit Type
Authorization
Permit Doc Type
Permit Document
Status
Ready to Film
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Oregon Department of Environmental Quality <br /> * The septic tank material is: <br /> x Concrete <br /> Steel <br /> Plastic <br /> Fiberglass <br /> Other(explain) <br /> Unknown <br /> * Is the septic tank accessible? x Yes No <br /> * Septic tank volume in gallons 1,000 <br /> * Tank volume determined by:Check all that apply,add comments below as needed <br /> Permit Records x Measured Stamped on Tank Other <br /> * Septic tank risers are at ground level x Yes No <br /> * Tank appears to be free from defects,leaking and signs of deterioration Yes x No <br /> If you answered"No,"please describe the condition of the septic tank below. For example, <br /> evidence of gas corrosion,cracks, leaks,etc. <br /> TANK IS SHOWING SIGNS OF DETERIORATION. <br /> * Septic tank lid(s)is intact x Yes No <br /> * Septic tank baffles are intact: Inlet x Yes No Outlet x fres No <br /> * Baffle material-Inlet L_X_. Plastic Concrete Metal <br /> Outlet X Plastic Concrete Metal <br /> * Effluent filter is present Yes No <br /> * Effluent filter is free of debris Yes No x Not applicable <br /> * Liquid level in tank relative to invert of outlet x At Above Below <br /> If above or below invert outlet,please explain: <br /> * Scum layer 3 (inches) Sludge layer 8 (inches) <br /> * Scum and Sludge layer more than 35%of the total tank volume Yes x No <br /> Indicate where sludge measured from: Inlet Middle x Outlet <br /> * Additional comments: <br /> PERFORMED 150-GALLON FLOW TEST WITH FLOW METER. <br /> 4. Dosing tank/Pump Basin <br /> Dosing tanks use a pump to send effluent to a treatment unit or soil absorption field. <br /> * The septic system has a dosing tank Yes x No <br /> (If"No,"skip the rest of section 4) <br /> * At the time of this evaluation the power was on to test the pump(s): Yes No <br /> Page 3 of 8 <br />