Septic Authorization 555-21-003820-AUTH Page 2 oft
<br /> ,.�,':SYv ux' A- z ✓z k<. i rix'« i "' Y s';7, r"*h� T-rW z G'i i- t h ",-;,P,: k} Rte.-d ,�' ,, -:.4}mss:
<br /> Date Issued 613/21 l'"--0-,',.----.Date Expiring 61,3/22 f "' �g ,,, : p � '� �'k .. `%" --.,, ' ,t 1 Z'-
<br /> F-. x k� ,A,ps.,id tlr' °ii.v.sr,..+ ..,r`' '4."t�.° vt3`s M4..r w °?TS .F..r'' 'S { ; 4 '�r� ,' $,ak a `'.t- fi'-.'' -4.1.4.".•,'°5S '�"_'e;.
<br /> WarI Description .° FIRE A.UTH W/FLDtREP( BURNEDYHOME.W/INISFD�3;BORM 0�•;c § A {f „
<br /> '. ,A;tksA kx l'x,,' "a 1,: . ..x1(� - 4 "`_etc X� sx; s?',V. r' w}^*� ' 4,,,4t i, .' .e. . ...r.,. y.1` .c.. r.':', , $>e t s
<br /> Conditions of Approval:
<br /> THIS SYSTEM IS AUTHORIZED FOR RECONNECTION UNDER OAR 340-071-205(4).
<br /> There will be no increase in flow as the 3 bedroom dwelling is being replaced with a new 3 bedroom dwelling. Under OAR
<br /> 340-71-0205(4),this system is not currently failing and meets current setbacks.
<br /> Marion County has records of the installation of this system including a Certificate of Satisfactory Completion dated July 29,
<br /> 1986, permit number 86-168.According to the inspection report the system consisted of 150 linear ft of drainline and a 1000
<br /> gallonseptic tank.The system was pumped and inspected on 4/1/2021 by A&B Septic.,The system was found to be in good
<br /> condition other than an equal distribution box that was replaced under this same permit number.
<br /> A site inspection conducted by Marion County on April 20,2021 found that previous records and the site plan are accurate, no
<br /> signs of failure were observed
<br /> This parcel was involved in the 2020 Beachie Creek Fire and the house was destroyed,it appears that septic drainfield and tank
<br /> were not damaged by the fire. Due to the Oregon Governor's executive order 20-60,a 10'setback from the existing drainfield to
<br /> the shop building is recommended but not currently required.
<br /> THE APPROVED SEPTIC SYSTEM AREA MUST BE PROTECTED from any vehicular traffic including construction vehicles,
<br /> livestock activities.Other activities such as logging,excavating or filling,driveway placement or any similar activities may also
<br /> damage the soil in the area and adversely affect the septic system approval. The areas of the initial septic system and the future
<br /> repair system must both be protected.
<br /> The septic tank should be pumped and inspected by a licensed septic tank pumping service approximately every five(5)years.
<br /> The septic tank is a reservoir for the solid materials in the sewage waste stream. Excessive accumulation of these solid
<br /> materials in the septic tank will cause the solids to wash out of the tank and into the drainfield. This will cause irreversible
<br /> damage to the drainfield and will eventually lead to a system failure.
<br /> Note:This Notice does not guarantee satisfactory or continuous operation of the sewage system.Should the system fail,a repair
<br /> permit from DEQ is required.
<br /> If you disagree with this report,you have the right to apply for an authorization notice denial review.The application for review
<br /> must be submitted in writing within 45 days of the report issuance and be accompanied by the review fee in OAR
<br /> 340-071-0140(3),Table 9C and any additional information DEQ needs to complete the review.
<br /> You may apply for a variance to the onsite wastewater treatment system rules. The variance application must include a copy of
<br /> the site evaluation report,plans and specifications for the proposed system,specify the rule(s)to which a variance is being
<br /> requested,demonstrate the variance is warranted,and include the variance fee in OAR 340-071-140 Table 9C. A variance may
<br /> only be granted if the variance officer determines that strict compliance with a rule is inappropriate or special physical conditions
<br /> render strict compliance unreasonable, burdensome or impractical. A senior DEQ variance officer will be assigned the variance
<br /> application.
<br /> Rob Goo Onsite Wastewater Specialist 2 6/3/21
<br /> �r - F[s-(oma CP5�0 /
<br /> 6 3��5.
<br /> 6/3/21:7:53:41AM Page 2 of 2 ONS_OnsiteAuthorizationpr